Glossary of Terms
ball26.gif (137 bytes) ASTM C-789:    This specification covers single-cell precast reinforced concrete box sections intended to be used for the construction of culverts and for the conveyance of storm water, industrial wastes, and sewerage.
ball26.gif (137 bytes) ASTM C-822:    Standard terminology relating to concrete pipe and related products.
ball26.gif (137 bytes) ASTM C-850:    This specification covers single-cell, precast reinforced concrete box sections with less than 2' of cover subjected to highway loading and intended to be used for the construction of culverts and for the conveyance of storm water, industrial wastes, and sewerage.
ball26.gif (137 bytes) ASTM C-969:    This practice covers procedures for testing installed precast concrete pipe sewer lines using either water infiltration or exfiltration acceptance limits to demonstrate the integrity of the installed materials and construction procedure.
ball26.gif (137 bytes) ASTM C-990:    This specification covers joints for precasr concrete pipe and box, and other sections using preformed flexible joint sealants for use in storm sewers and culverts which are not intended to operate under internal pressure, or are not subject to infiltration or exfiltration limits. Joint material used in horizontal applications is intended to prevent the flow of solids through the joint.
ball26.gif (137 bytes) ASTM C-1214:   This test method covers procedures for testing concrete pipe sewer lines when using the negative air pressure (vacuum) test method to demonstrate the integrity of the installed material and the construction procedures. This test method covers testing of 4" to 36 " diameter circular concrete pipe sewerlines utilizing gasketed joints.  
ball26.gif (137 bytes) AWWA C-302:   
ball26.gif (137 bytes) Concrete Cylinders:    This a test of concrete strength whereby molds are filled with the concrete to be tested via specification, then curred for a designated period of time, and finally crushed for final results.
ball26.gif (137 bytes) Cores:    Cores are samples drilled from the actual product and crush tested for strength
ball26.gif (137 bytes) Dry Cast:    Method of producing concrete products with zero slump concrete either mechanically or poured.
ball26.gif (137 bytes) Jacking Pipe:    Special designed reinforced concrete pipe which posesses thrust load capabilities for a specified project.
ball26.gif (137 bytes) Sanitary Sewer:    Sewers designed for the transportation of contaminated waters and wastes to treatment plants,septic, anaerobic, or aerobic  disposal systems.
ball26.gif (137 bytes) Storm Sewer:    Sewers designed for the removal of uncontaminated run off waters to retention areas, creeks, rivers, etc.
ball26.gif (137 bytes) T-Lock:    Liners made of a durable plastic composition which have a " T " designed rear side and is cast into the concrete giving the liner its locking capability and its name. 
ball26.gif (137 bytes) 2- Z Specification:    This is a specification established by the Water Reclamation District of the Greater Chicagoland Area for hydrostatic testing of product they purchase. Concrete pipe is separated a distance of 2 times their 'Z' dimension, filled with water to a prescribed level, then pressurized to 15lb psi for 2 hours without leaking through the walls or joints.
ball26.gif (137 bytes) 3-Edge Bearing:    Method of testing the strength of concrete pipe by squeezing the product on a rack until a .01" crack appears or squeezing until the product shows complete failure.
Wet Cast:    Method of producing concrete products with greater than zero slump concrete in the poured fashion.

 

Return to Glossary - Page One

Contact Information

National Concrete Pipe Company's operation facility is staffed 18 hours each day, 6 days per week. In addition, the office is in operation from 5am until 5pm, 5 days per week. National Concrete Pipe Company can be reached via E-mail, web site, and Fax 24 hours a day, 7 days per week.

National Concrete Pipe Company
11825 Franklin Park,
Franklin Park, IL  60131
phone: 630-766-3600

fax: 630-766-6197
e-mail us at: johne@nationalconcretepipe.com

[home] [about us] [sales] [product info] [contact us] [news] [glossary] [gallery]